2. Grasp the handles on the toner cartridge and pull to remove the
cartridge from the machine.
3. Holding both handles on the toner cartridge, thoroughly rock it from side
to side to evenly distribute the toner.
4. Slide the toner cartridge back into the machine.
5. Close the front cover. Make sure the cover is securely latched.
REPLACING THE TONER CARTRIDGE
The machine uses four colors and has a different toner cartridge for each
one: yellow (Y), magenta (M), cyan (C), and black (K).
The status LED and the toner-related message on the display indicates
which each individual toner cartridge should be replaced.
Incoming incoming faxes are saved in memory.
saved in memory.
At this stage, the toner cartridge needs to be replaced. Check the type of
toner cartridge for your machine. (See "" on page 90.)
1. Turn the machine off, then wait a few minutes for the machine to cool.
2. Using the handle, completely open the front cover.
When you open the front cover, be careful not to touch the
underneath of the control panel (the lower part of the fuser unit). The
temperature of the fuser unit might be high and could damage your
skin.
When you open the front cover and work inside the machine, it is
highly recommend that you remove the paper transfer belt first.
Because the work you do could contaminate the paper transfer belt.
If toner gets on your clothing, wipe it off with a dry
cloth and wash it in cold water. Hot water sets toner into
fabric.
If the front cover is not completely closed, the machine will not
operate.
Do not touch the green surface, the OPC drum or the front of
each toner cartridge, with your hands or any other material. Use
the handle on each cartridge in order to avoid touching this area.
Be careful not to scratch the surface of the paper transfer belt.
If you leave the front cover open for more than a few minutes, the
OPC drum can be exposed to light. This will cause damage to the
OPC drum. Close the front cover should the installation need to
be halted for any reason.