Muratec F-565 Specifications Page 367

  • Download
  • Add to my manuals
  • Print
  • Page
    / 383
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 366
5-77
5.3.4 Zoom adjustment
FBS zoom adjustment (Vertical)
L R
2003-01
NO.20031021
1.401.251.000.750.550.400.350.300.250.200.150.10
1.401.251.000.750.550.400.350.300.250.200.150.10
A
Note: This adjustment must be made after the adjustments of printer registration (top and side) of the 1st cassette
have been made.
The difference should be within ± 1.0% of the actual length of A on the test chart No. 2003-01.
Adjust so that the following specifications are satisfied with the length of A on the test chart
No.2003-01.
Zoom ratio Standard Adjustment Tool Setting Range
100 % ± 1.0 % Machine parameter:017
– 1.5 to 1.5 %
(0.1 % step)
Adjustment procedure
1. Load legal (for USA version) or A4 (for GBR version) size paper to the first cassette.
2. Place the Muratec Test Chart No. 2003-01 on the FBS.
3. Make two copies on paper in the 1st cassette with 100 % magnification.
4. Measure the length of A on the second copy to find the difference.
If length A falls outside the specified range, perform the following steps to make the adjustment.
5. Enter Machine Parameter mode. (Press <Setting>, <*>, <0>, <0>)
6. Adjust so that the setting of Machine Parameter 017 meets the specification.
If length A is shorter than the standard, increase value.
If length A is longer than the standard, decrease value.
Page view 366