Muratec F-565 Specifications Page 94

  • Download
  • Add to my manuals
  • Print
  • Page
    / 383
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 93
3-10
Machine Parameter 020
Switch
Initial
Setting
Adjust Usage/Comments
7 1 Mirror carriage standby
position adjustment
Adjusts the number of the
steps from the home sensor
of the mirror carriage OFF
to the standby position.
1 step = 0.0212 mm
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Switch 76543210 Settings
127steps 01111111 +17.89 mm
:
80 steps 01010000 +11.26 mm
:
50 steps 00110010 +7.04 mm
:
20 steps 00010100 +2.82 mm
:
10 steps 00001010 +1.41 mm
:
3 steps 00000011 +0.42 mm
2 steps 00000010 +0.28 mm
1 step 00000001 +0.14 mm
00000000 9.15 mm
When Switch 7 is “1”, it means “ - ”. For example,
“10000001” means “-0.14 mm”.
6 0
5 0
4 1
3 0
2 1
1 1
0 1
Machine Parameter 021
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Mirror carriage transfer mode
position adjustment
Adjusts the number of the
steps from the home sensor
of the mirror carriage OFF
to the transfer mode position.
1 step = 0.0212 mm
Switch 76543210 Settings
127steps 01111111 +2.70 mm
:
64 steps 01000000 +1.36 mm
:
32 steps 00100000 +0.68 mm
:
16 steps 00010000 +0.34 mm
:
8 steps 00001000 +0.17 mm
:
00000000 21.5 mm Initial setting
:
-8 steps 10001000 -0.17 mm
:
-16 steps 10010000 -0.34 mm
:
-32 steps 10100000 -0.68mm
:
-64 steps 11000000 -1.36 mm
:
-127steps 11111111 -2.70mm
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Machine Parameter 022 ~ 024 — Factory use only
Page view 93