12-3Ma I n t e n a n c e & pr o b L e M s o L v I n G
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
Ma I n t e n a n c e & pr o b L e M s o L v I n G
Cleaning the ADF rollers
If you are having trouble with getting your documents to feed properly, try this proce-
dure:
1
Turn off the power and disconnect the power cable from the wall outlet.
2
Open the ADF cover.
3
Use a cloth moistened with a rubber roller cleaner to clean the face of the rollers.
Rotate the rollers by hand to allow cleaning of the entire roller surface.
Cleaning the drum charge wire and the print head
When the following message appears on the LCD or if there are any poor print quality
on your print, the charge wire of the drum cartridge requires cleaning.
Open Front Cover
Follow Instruction A
NOTE: Your machine can print about 100 sheets after this message appears, but afterwards
the machine displays “Printer Not Usable” message and it cannot print any page
until the charge wire is cleaned.
To clean the charge wire
1
Open the front cover.
2
Gently pull the blue cleaning rod toward you, making sure it fully extends. Then
return the rod to its original position.
This operation also clean the print head.
Pull the blue rod toward
you,making sure it fully
extends.
Return the rod to its
original position.
Instruction
A
1
2
3
Close the front cover.
Page view 166