3-82
3.18 Clear Optional Data
This mode clears all data and all activity journals for optional RS-232C, Printer controller and second phone
line.
Note: Second phone line is available only for the MFX-1700/MFX-1600.
1. Press Program key, *, I (09).
Option Data Initial
Check Enter/Cancel
2. Press ENTER. The optional data will be cleared.
Note: To finish the operation without performing initialization, press CANCEL.
3.19 Set Service Code
This is the code which, one can protect the life monitor clear operation. If it is not necessary to protect to the
life monitor clear operation, abort this operation without entering the service code.
1. Press Program key, *, J (10).
Set Service Code
Old Passcode :*
***
2. Your next mode depends on whether youre creating or modifying the service code:
If creating --- Use the numeric keypad to enter 0000 and press ENTER.
If modifying --- Use the numeric keypad to enter the proper service code and press ENTER. If you
enter an invalid code, the fax will reject the attempt and abort this operation.
3. Use the numeric keypad to enter the four-digit service code.
Set Service Code
New Passcode :1
234
4. Press ENTER.
Note: To turn off the service code and return to normal life monitor clear (not protect), change the code to
0000 by repeating steps 1-4 and entering 0000 in step 3.