3-24
Memory Switch B:5 - Transmission
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Program individual autodialer
attributes
0: No
1: Yes
Allows individual setting of memory switches B:0 as
attribute 1, B:1 as attribute 2, B:2 as attribute 3 and
B:3 as attribute 4 when one-touch and speed dial
locations are programmed. (Refer to page 3-35 for
settings.)
6 0 Factory use only
5 0 Factory use only
4 0 Factory use only
3 0 Factory use only
2 0 Sending RTC signal when
transmission is canceled
0: Yes
1: No
RTC signal is sent at the end of the transmission.
When set at “0”, the unit will send the RTC if the
transmission is canceled. No error will occur. When
set at “1”, an error will occur because RTC will not
be sent at the end of a canceled transmission.
1 1 Cancel redial if T.4.1 or T.4.4
error occurs
0: Yes
1: No
When set at “0”, if a T.4.1 or T.4.4 error occurs, the
unit will not retry the transmission.
0 0 Action after EOR signal
0: Continue
1: Discontinue
Sets action after receiving PPR four times at 2400
bps.
Memory Switch B:6 - Transmission
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Factory use only
6 0 Factory use only
5 0 Factory use only
4 1 Factory use only
3 1 Additional data on TTI
transmit
0: No
1: Yes
When set at “0”, the transmission of the additional
data (time, the number of pages, file number, etc)
is disabled.
Note: This switch is available only when Memory
switch B:2, bit 4 is available.
2 1 Subscriber ID transmit
0: No
1: Yes
When set at “0”, the transmission of the subscriber
ID is disabled.
Note: This switch is available only when Memory
switch B:2, bit 4 is available.
1 1 TTI (name) transmit
0: No
1: Yes
When set at “0”, the transmission of the name
which was stored in the unit is disabled.
Note: This switch is available only when Memory
switch B:2, bit 4 is available.
0 0 Factory use only
Memory Switch B:7
B:9 --- Factory use only