3-17
Machine Parameter J:3
Switch
Initial
Setting
Adjust Usage/Comments
7 1
6 0
5 0
4 0
3 0
2 1
1 0
0 0
Printer registration
adjustment (Horizontal) at the
optional second cassette.
Adjusts the start point to
print.
The plus setting increase the
left margin and the minus
setting decrease it.
Each setting changes by
0.5 mm
Switch 76543210 Settings
00001000 4.0 mm Maximum
|
|
00000010 1.0 mm
00000001 0.5 mm
00000000 0.0 mm
10000001 -0.5 mm
10000010 -1.0 mm
10000011 -1.5 mm
10000100 -2.0 mm
Initial setting
10000101 -2.5 mm
10000110 -3.0 mm
10000111 -3.5 mm
10001000 -4.0 mm Minimum
Machine Parameter J:4
Switch
Initial
Setting
Adjust Usage/Comments
7 1
6 0
5 0
4 0
3 0
2 0
1 0
0 1
Printer registration
adjustment (Horizontal) at the
bypass tray
Adjusts the start point to
print.
The plus setting increase the
left margin and the minus
setting decrease it.
Each setting changes by
0.5 mm
Switch 76543210 Settings
00001000 4.0 mm Maximum
|
|
00000100 2.0 mm
00000011 1.5 mm
00000010 1.0 mm
00000001 0.5 mm
00000000 0.0 mm
10000001 -0.5 mm
Initial setting
10000010 -1.0 mm
10000011 -1.5 mm
10000100 -2.0 mm
|
|
10001000 -4.0 mm Minimum
Machine Parameter J:5 ∼
∼∼
∼ J:9 --- Factory use only