3.10.1 Life Monitor
The life monitor displays the current software version, the total number of pages scanned, printed, and
transmitted, the number of drums replaced and the total page count on the current drum.
Note: The All RAM Clear setting does not clear the life monitor. To clear, see below.
1. Press MENU, *, 0, 9, ENTER.
No. ?
2. Press the number to select the desired display.
The following options are available:
00 = displays software version
01 to 02 = displays software version of the optional kit
11 = displays machine’s serial number
12 = displays installation date
13 = displays total pages scanned
14 = displays total pages printed
15 = displays total pages transmitted
16 = displays drum replaced
17 = displays total pages printed on current drum
18 = displays toner replaced count
19 = displays toner life
20 = displays fuser replaced count
21 = displays fuser life
22 = displays transfer roller replaced count
23 = displays transfer roller life
3. Press MENU to exit the display life monitor