3-20
Machine Parameter 182 186 --- Factory use only
Machine Parameter 187
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Printer registration
adjustment (Vertical) at the
Bypass tray for printing.
Adjusts the start point to
print.
The plus setting increases
the top margin and the minus
setting decreases it.
Each setting changes by
0.1 mm.
Note: See Machine
Parameter 197 for the rotate
printing.
Switch 76543210 Settings
127 steps 01111111 +12.7 mm
:
32 steps 00100000 +3.2 mm
:
16 steps 00010000 +1.6 mm
:
8 steps 00001000 +0.8 mm
:
00000000 0 mm Initial setting
Note: Set this switch after setting the margin to
“0 mm” in Unique Switch 052. Then, after setting
this switch, set the margin to the initial setting (4
mm) in Unique Switch 52.
Machine Parameter 188
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Printer registration
adjustment (Vertical) for
duplex printing cassette.
Adjusts the start point to
print.
The plus setting increases
the top margin and the minus
setting decreases it.
Each setting changes by
0.1 mm.
Note: See Machine
Parameter 197 for the rotate
printing.
Switch 76543210 Settings
127 steps 01111111 +12.7 mm
:
32 steps 00100000 +3.2 mm
:
16 steps 00010000 +1.6 mm
:
8 steps 00001000 +0.8 mm
:
00000000 0 mm Initial setting
Note: Set this switch after setting the margin to
“0 mm” in Unique Switch 052. Then, after setting
this switch, set the margin to the initial setting (4
mm) in Unique Switch 52.
Machine Parameter 189 and 219 --- Factory use only