THERMISTOR/ THERMO
1) Open the Cover jam access.
2) Remove the Printer fuser. (See page 5-52)
3) Remove the Sensor thermo mounting screw, and then remove the Thermistor.
Sensor thermo
Printer fuser
4) Remove two Frame fuser outer mounting screws, and then remove the Frame fuser outer.
5) Remove two Roller heat mounting screws, and then remove the Roller heat.
6) Remove two Thermo mounting screws, and then remove the THERMO.
Frame fuser outer
Frame fuser inner
Roller heat
Thermo