3-10
Machine Parameter 025
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Background level adjustment
starting position
Adjusts the number of the
steps from the home sensor
of the mirror carriage OFF
to the background level
adjusting start position.
1 step = 0.0212 mm
Switch 76543210 Settings
127steps 01111111 +2.70 mm
:
64 steps 01000000 +1.36 mm
:
32 steps 00100000 +0.68 mm
:
16 steps 00010000 +0.34 mm
:
8 steps 00001000 +0.17 mm
:
00000000 15.35 mm Initial setting
:
-8 steps 10001000 -0.17 mm
:
-16 steps 10010000 -0.34 mm
:
-32 steps 10100000 -0.68mm
:
-64 steps 11000000 -1.36 mm
:
-127steps 11111111 -2.70mm
Machine Parameter 026 029 --- Factory use only