3-26
Machine Parameter 287
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Transfer current adjustment
for postcards
The plus setting increases
the current and the minus
setting decreases it.
Each setting changes by
0.11 µA.
When transfer problems occur, adjust this
parameter.
Switch 76543210 Settings
31 steps 00011111 +3.41 µA
:
8 steps 00001000 +0.88 µA
:
00000000 0 µA Initial setting
-1 steps 10000001 -0.11 µA
-2 steps 10000010 -0.22 µA
:
-8 steps 10001000 -0.88 µA
:
-31 steps 10011111 -3.41 µA
When Switch 7 is “1”, it means “ - ”. For example,
“10000001” means “-0.11 µA”.
NOTE: Adjusting them too many steps effect the
print quality. Just try to decrease one or two steps
at first.
Machine Parameter 288
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Transfer current adjustment
for transparency sheets
(OHP)
The plus setting increases
the current and the minus
setting decreases it.
Each setting changes by
0.11 µA.
When transfer problems occur, adjust this
parameter.
Switch 76543210 Settings
31 steps 00011111 +3.41 µA
:
8 steps 00001000 +0.88 µA
:
00000000 0 µA Initial setting
-1 steps 10000001 -0.11 µA
-2 steps 10000010 -0.22 µA
:
-8 steps 10001000 -0.88 µA
:
-31 steps 10011111 -3.41 µA
When Switch 7 is “1”, it means “ - ”. For example,
“10000001” means “-0.11 µA”.
NOTE: Adjusting them too many steps effect the
print quality. Just try to decrease one or two steps
at first.
Comments to this Manuals