5-51
5-51
SENSOR PSS
1) Remove the Cover jam access.
2) Remove the Guide press B mounting screw, and then remove Guide press B while pulling up the Feeler
PSS.
3) Release the tab, and then remove the SENSOR PSS.
Feeler PSS
Guide press B
Sensor PSS
Sensor stopper
ROLLER PICKUP MP / PAD PRESSURE MP
1) Remove the Clutch (MG) (See page 5-42)
2) Remove the Cover jam access.
3) Remove two E-rings.
4) Lift the Guide paper MPDUP and press down the MP pressure.
5) Slide the ROLLER PICKUP MP to the left and remove.
Clutch(MG)
E-ring
E-ring
Roller pickup MP
MP pressure
Guide paper MPDUP