Muratec MFX-1500 User Manual Page 103

  • Download
  • Add to my manuals
  • Print
  • Page
    / 147
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 102
eyon
e
as cs
2.58
6
Use the numeric keypad to enter your F-Code’s four-digit passcode. Here
we’ve entered
2345
:
03:Print F-Code Doc.
F-Code Passcode:2345
7
Press
ENTER
.
If you’ve entered the correct passcode, your fax machine will print all
documents in — and then erase them from — the mailbox.
If you’ve entered an incorrect passcode, your fax machine will refuse to
print the document.
F-Code transmission and polling
With F-Code, your machine — in addition to sending Muratec-proprietary
SecureMail (
pages 2.38–2.41
) and performing database polling (
pages 2.31–2.32
)
from only other Muratec models — can send secure transmissions to, and perform
database polling from, other makers’ machines, as well. You may accomplish such
transmissions in either of two ways:
Programmable one-touch key (see pages 2.67–2.69)
Direct entry of the
ITU
-
T
subaddress and password, which is what we will
now describe.
Whether you are sending to or polling from another machine, you obviously must
know the correct sub-address on the receiving machine, as well as the password if
that sub-address has one. (This is analogous to how, with Muratec SecureMail, you
must know the correct SecureMail mailbox number and password on the remote
Muratec fax.)
Note:
For F-Code communication to occur, three things must be true:
The remote fax machine must support
ITU
-
T
sub-addressing (and
password) capabilities.
A mailbox with an
ITU
-
T
sub-address
must
exist on the remote fax. (It
doesn’t have to have a password. If the other machine hasn’t at least one
box with a sub-address, F-Code communication will be impossible.)
You must know the
ITU
-
T
sub-address and (if applicable) password
information for the mailbox on the remote machine.
F-Code transmission
1.
Press
COPY
/
FA X
to change to Fax mode, if necessary.
2.
Insert the document.
3.
Adjust resolution and contrast if necessary.
4.
If you wish to toggle between transmission from the feeder and
transmission from memory, press
MEMORY TRANSMIT
.
Note:
This toggle affects only a transmission from the
ADF
. Transmission
from the
FBS
is always memory transmission.
5.
Press
COMMUNICATION OPTIONS
seven times and then press
ENTER
.
7.F-Code TX
Comm.Option/Enter
6.
Press
ENTER
.
Enter Sub-Address
_
7.
Use the numeric keypad to enter the appropriate sub-address number. In
this example, we’ve entered
123456.
Enter Sub-Address
123456_
Note:
If you make a mistake, press
CANCEL
to back up, then enter the
correct one-digit number.
8.
Press
ENTER
. The display will show:
Enter Password
_
Note:
If you know that this sub-address does
not
have a password, skip
to step 10.
9.
Use the numeric keypad to enter the appropriate password number. In this
example, we’ve entered
654321
.
Enter Password
654321_
Note:
If you make a mistake, press
CANCEL
to back up, then enter the
correct one-digit number.
10.
Press
ENTER
. The display will show:
Enter Fax Number
_
11.
Enter the fax number either by pressing a one-touch key, entering a speed-
dial number or dialing from the numeric keypad. Do not press
START
.
12.
What you do now depends upon when you wish the transmission to begin.
To have it begin now, skip to step 15.
To delay it, proceed to step 13.
Page view 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 146 147

Comments to this Manuals

No comments